Nanomechanical Testing Journal Club

Ultrahigh Cycle Fatigue Deformation of Polycrystalline NiTi Micropillars

by Peng Hua, Hongyang Lin, and Qingping Sun

Key Points

  • Researchers were able to make useful comparisons in mechanisms at the microscale and bulk scale;
  • Fatigue mechanisms were observed to be drastically different due to the reduction in scale; and
  • Sample dimensions can change the fatigue performance and mechanisms of a material under stress.

 Receive future Journal Club updates via email

Scripta Materialia July 2021
DOI: 10.1016/j.scriptamat.2021.114108

Shape memory alloys (SMA) are an important class of materials, largely owing to their superelastic behavior based upon recoverable phase transformations. However, they can be susceptible to fatigue failure at the bulk scale due to crack nucleation and growth strongly related to local defects.

For the 2x2x4 µm pillars tested in this study, the fatigue mechanisms were observed to be drastically different due to the reduction in scale. NiTi is commonly used at the microscale, in thin films, wires, and MEMS devices, so these findings have practical implications besides furthering the understanding of fatigue in SMAs.

Two stress levels (1 and 1.5 GPa) were utilized for cyclic loading, and pillar heights were measured with a Bruker NPFLEX 3D surface profilometer. It was found in both cases that the amount of hysteresis and the transformation stresses and strains decrease with number of cycles, due to functional degradation from the accumulation of permanent deformation. This deformation was thoroughly characterized by post-mortem TEM and was found to consist of both dislocation plasticity and residual martensite. By heating the pillars at 150°C, a large amount of the functional degradation was reversed as the martensite gets reverted back to austenite. This allowed the researchers to make useful comparisons in mechanisms at the microscale and bulk scale.

The experimental work was conducted using a Hysitron TI 980 TriboIndenter on FIB‑prepared micropillars using the nanoDMA option to achieve 108 loading cycles at 200Hz-325Hz.

      KEY TERMS:

  • Shape memory alloys, Fatigue deformation, Functional degradation, Micropillars, Phase transformation