Bruker
Products & Solutions
Applications
Services
News & Events
About
Careers
Probes

Micro2.5 - Magic Angle Spinning

Fusing Magic Angle Spinning (MAS) technology with the MR Microscopy gradient technology enables to acquire images and localized spectra of semi-solid objects due to the combination of reduced signal linewidth with a high and very linear gradient field. Rotors with a 3.2 or 4 mm diameter are offered, further on request. Besides imaging applications very slow diffusion processes can be investigated applying the strong gradient fields.
Picture 42

Highlights

Fusing Magic Angle Spinning (MAS) technology with the MR Microscopy gradient technology enables to acquire images and localized spectra of semi-solid objects due to the combination of reduced signal linewidth with a high and very linear gradient field. Rotors with a 3.2 or 4 mm diameter are offered, further on request. Besides imaging applications very slow diffusion processes can be investigated applying the strong gradient fields.

It is combined with Bruker’s Micro2.5 WB gradient system, which is the MR Microscopy gradient workhorse. Its gradient strength is perfect for most applications. Utilizing the Micro2.5 gradient the maximum gradient strength of 2.5 T/m along the magic angle is reached if the x, y, z gradients are switched simultaneously. 

The MR Microscopy MAS Probe is a very dedicated and customized device. Please contact the MR Microscopy Product Management before placing an order.

Applications

Applications

The MR Microcopy Micro2.5 Magic Angle Spinning probe offers unique capabilties for imaging and diffusion experiments of semi-solid objects. 

Pulsed-Field-Gradient NMR with Magic-Angle Spinning.

http://hdl.handle.net/11858/00-001M-0000-0010-D3C3-D

Stress Dependence of 1H Diffusion in Silicon Rubber using MAS (check)

m13

Metabolite localization in living drosophila using High Resolution Magic Angle Spinning NMR

https://doi.org/10.1038/srep09872

Specifications

Specifications

Micro2.5 Magic Angle Spinning  
Bore     WB / SWB
1H frequency range 300 – 800 MHz
rf channels Two independent
Requirements Microscopy Accessory
Gradient     Micro2.5    
Directions     xyz    
Gradient strength per direction 1.5 T/m
ID/OD 40/72 mm
Rise Time (5-95%), 0-60A,120V < 100 µs
Cooling     Water    
Maximum current tested 60 A
Removable     Yes    

Accessories

Accessories

  • MAS-3 Unit -> Link to MAS-3 / or solids page

Support

Labscape

Service & Life Cycle Support for Magnetic Resonance and Preclinical Imaging

Bruker’s commitment to provide customers with unparalleled help throughout the buying cycle, from initial inquiry to evaluation, installation, and the lifetime of the instrument is now characterized by the LabScape service concept.

LabScape Maintenance Agreements, On-Site On-Demand and Enhance Your Lab are designed to offer a new approach to maintenance and service for the modern laboratory