BBFO-CRP_Banner.jpg

Highest NMR sensitivity for the periodic table of NMR

The new BBO CryoProbe offers the highest commercially available sensitivity for the broadest range of nuclei, designed for both observe and inverse detection

The new BBO CryoProbes offers the highest commercially available sensitivity for the broadest range of nuclei, designed for both observe and inverse detection.

The BBO CryoProbe is designed for highest sensitivity on the broadest range of nuclei. Besides 1H and 19F, all NMR nuclei in the range 31P to 15N can be observed / irradiated, except the frequency range between 199Hg and 153Eu. All of these nuclei can be fully automatically selected and optimally tuned and matched by using the ATM option.

Concerning 19F observation and decoupling Bruker offers two different BBO CryoProbe design: The BBFO and BBO H&F.

BBFO has the capacity to observe 1H with 19F decoupling (and vice-versa) and to perform one or higher dimensional 1H/19F spectroscopy with optimal quality.

 

BBO H&F was designed for enhanced 19F and 13C sensitivity compared to BBFO. 19F can be adjusted via tuning the 1H channel to 19F. Of course 1H observe with 19F decoupling (and vice-versa) is no longer possible but besides the standard experiments BB observe with 1H decoupling the BBO H%F is capable for BB observe with 19F decoupling.

Hence the BBO CryoProbe is destined to be your workhorse probe for routine NMR with high sensitivity and/or high throughput. In addition it provides a great solution for research applications on less commonly measured nuclei as well as low natural abundance / low sensitivity nuclei.

BBFO CryoProbe

  • Sensitivity increase by a factor of about three-four* in the range 31P to 15N
  • Sensitivity increase by a factor of about three* on 1H
  • Two fully independent channels (plus lock channel)
  • Optimal quality on experiments with 1H observation with 19F decoupling (and vice-versa)
  • Cold preamplifiers for all nuclei (BB-range, 19F, 1H and 2H)
  • Cooled 2H preamplifier for excellent stability
  • Fitted with an actively shielded single axis Z-gradient for 5 mm sample diameters
  • Standard sample temperature range -40°C – 150°C
  • ATM compatible

*compared to the SmartProbe

BBO H&F CryoProbe

  • Sensitivity increase by a factor of more than four* in the range 31P to 15N
  • Sensitivity increase by a factor of more than three* on 1H
  • Sensitivity increase by a factor of more than six* on 19F
  • Two fully independent channels (plus lock channel)
  • Optimal quality on experiments with BB observation with 1H or 19F decoupling (and vice-versa)
  • Cold preamplifiers for all nuclei (BB-range, 1H and 19F, 2H)
  • Cooled 2H preamplifier for excellent stability
  • Fitted with an actively shielded single axis Z-gradient for 5 mm sample diameters
  • Standard sample temperature range -40°C – 150°C
  • ATM compatible

*compared to the SmartProbe

LabScape

Service & Life Cycle Support for Magnetic Resonance and Preclinical Imaging

Bruker’s commitment to provide customers with unparalleled help throughout the buying cycle, from initial inquiry to evaluation, installation, and the lifetime of the instrument is now characterized by the LabScape service concept.

LabScape Maintenance Agreements, On-Site On-Demand and Enhance Your Lab are designed to offer a new approach to maintenance and service for the modern laboratory

Download LabScape Brochure