Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
superconducting (SC) NMR Magnets | all non-shielded | 100...600 MHz; all bore diameters |
2000 | 2000 | 31.12.2017 | ** | UltraShield™ (US) SC NMR Magnets |
SC NMR Magnets |
Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
D-Series | DPX all |
2000 | 2001 | 31.12.2016 | ** | Avance™ Series | DPX | |
D-Series |
DRX all |
2000 | 2002 | 31.12.2016 | ** | Avance™ Series | DRX | |
D-Series | DMX all |
2000 | 2002 | 31.12.2016 | ** | Avance™ Series | DMX | |
D-Series | DSX all |
2000 | 2002 | 31.12.2016 | ** | Avance™ Series | DSX | |
Avance™ | I | all | 2004 | 2005 | 31.12.2016 | ** | Avance™ II | Avance I |
Avance™ | II | all | 2006 | 2007 | 31.01.2018 | ** | Avance™ III | Avance II |
Avance™ | III | all | 2012 | 2013 | 31.12.2024 | ** | Avance™ III HD | Avance III |
Avance™ | III HD | all | 2017 | 2019 | 31.12.2029 | ** | Avance™ NEO | III HD |
Fourier | 300 | all | 2015 | 2016 | 31.12.2020 | ** | Fourier 300 HD | Fourier 300 |
Fourier | 300 HD | all | Jan 2018 | Dec 2019 | 31.12.2029 | ** | Avance™ NEO 300 | 300 HD |
Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
Cryoprobe Cooling Unit | CU | CU/1 |
2001 | 2002 | 31.12.2013 | ** | Cooling Unit CU/2 | |
Cryoprobe Cooling Unit | CU | CU/2 |
2005 | 2005 | 31.01.2018 | ** | Cooling Unit CU/3 | CU/2 |
Cryoprobe Cooling Unit | CU | CU/3 |
2006 | 2007 | 31.01.2018 | ** | Cooling Unit CU/4 | CU/3 |
Cryoprobe Cooling Unit | CU | CU/4 | 2017 | 2017 | 31.01.2027 | ** | Cooling Unit CU/5 | CU/4 |
Bruker Magnet Pump Control | BMPC | BPMC1 | 2006 | 2006 | 31.01.2019 | ** | BMPC2 | BMPC1 |
Comment: Technical restrictions make it impossible to repair the listed BCU types. The last delivery date refers to the one of the latest model of the type. There are models where deliveries stopped as early as 2011.
Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
Solid-State Probe | MASDVT | all diameters | 2008 | 2009 | 31.12.2019 | ** | please contact Bruker + | MASDVT |
Solid-State Probe | MASVTN | all diameters | 2008 | 2009 | 31.12.2019 | ** | please contact Bruker + | MASVTN |
Solid-State Probe | MASWVT | all diameters | 2008 | 2009 | 31.12.2019 | ** | please contact Bruker + | MASWVT |
Solid-State Probe | TRIGAMMA I | all diameters | 2012 | 2012 | 31.12.2018 | ** | TRIGAMMA II (2nd Generation) | TRIGAMMA |
Solid-State Probe | MASCAT I | all diameters | 2013 | 2013 | 31.12.2018 | ** | MASCAT II (2nd Generation) |
MASCAT |
Solid-State Probe | MAS VTN 400-600MHz BL4 |
N-P/H and N-P/H-F | 2021 | 2022 | 31.12.2024 | ** |
iProbe CP-MAS |
|
S-State Probe Accessory | MAS I Unit (H2620) | all versions | 2004 | 31.12.2018 | ** | MAS 3 Unit | MAS I | |
S-State Probe Accessory | MAS II Unit (H13000) | all versions | 2013 | 2014 | 31.12.2018 | ** | MAS 3 Unit | MAS II |
Helium Cryo Probe (1st Generation) | CP…TXI, CI, TFI, TXO |
for Systems 400...950MHz, - all length - |
2009 | 2009 | 31.12.2019 | ** | Helium Cryo Probes (2nd Generations) | CP2 |
Helium Cryo Probe (1st Generation) | CP…DUL, DUX, DCH, DUI |
for Systems 400...950MHz, - all length - |
2009 | 2009 | 31.12.2019 | ** | Helium Cryo Probes (2nd Generations) | CP2 |
Helium Cryo Probe (1st Generation) |
CP…SEX, SEF, SEI |
for Systems 400...950MHz, - all length - |
2009 | 2009 | 31.12.2019 | ** | Helium Cryo Probes (2nd Generations) | CP2 |
Helium Cryo Probe (1st Generation) | CP…QNP, QDCI |
for Systems 400...950MHz, - all length - |
2009 | 2009 | 31.12.2019 | ** | Helium Cryo Probes (2nd Generations) | CP2 |
Helium Cryo Probe (1st Generation) | CP…MIC |
for Systems 400...950MHz, - all length - |
2009 | 2009 | 31.12.2019 | ** | Helium Cryo Probes (2nd Generations) | CP2 |
High Power Diffusion Probe Diff30 | Diffusion Probe | 2016 | 2017 | 31.12.2023 | ** | High Power Diffusion Probe DiffBB |
Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
EMX™ | EMX™ series | all - with transputer interface | 2002 | 31.12.2017 | ** | EMXplus™/EMXmicro™ with ethernet interface |
EMX | |
EMXnano™ | EMXnano™series | all variants | Jan 2021 |
Dec 2021 |
31.12.2028 |
** | ESR5000™ | |
ELEXSYS™ | ELEXSYS™ series | all - with transputer interface | 2002 | 31.12.2017 | ** | ELEXSYSTM |
ELEXSYS | |
ELEXSYS™ |
ELEXSYS™ series |
all - with ethernet interface |
2009 |
2009 |
31.12.2021 |
** |
ELEXSYS-II™ |
|
e-scan™ | e-scan™ series | Beer Analyzer | Mar 2018 | Dec 2018 | 31.12.2025 | yes | microESR™ | e-scan Beer Analyzer |
e-scan™ | e-scan™ series | Alanine Dosimetry Reader | Mar 2018 | Dec 2018 | 31.12.2025 | ** | ESR5000D™ | |
e-scan™ | e-scan™ series | E, F, M, R | Mar 2018 | Mar 2018 | 30.03.2025 | ** | E, F: microESR™, M, R: ESR5000™ or microESR™ | |
Magnettech | MiniScope MS series | MS100, MS200, MS300 | 2011 | 2011 | 31.12.2020 | ** | ESR5000™ | |
Magnettech | MiniScope MS series | MS400 | 2017 | 2017 | 31.12.2022 | ** | ESR5000™ |
Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
minispec® | NB system | 1999 | 2002 | 31.12.2012 | ** | ND system | NB system | |
minispec® | mq Series | ND system | 2010 | 2013 | 31.12.2020 | yes | NF system | ND system |
minispec® | mq Series | NF system until s/n 4148 | --- | 2015 | 31.12.2022 | no | NF system | NF system |
minispec® | mq Series | Profiler for NF Systems | 2020 | 2020 | 31.12.2027 | no | none | NF system |
minispec® | mq Series | MQ10, MQ20 LS33 and MQ40 incl. Probes | 2022 | 2022 | 31.12.2028 | no | none | NF system |
minispec® | LF Series | LF 65 | 2022 | 2022 | 31.12.2028 | no | none | NF system |
minispec® | mq-one Series | Seed Analyzer | 2022 | 2022 | 31.12.2028 | no | none | NE system |
minispec® | LF Series | LF 50 H | 2024 | 2025 | 31.12.2030 | no | none | NF system |
Technique | Method | Product | Series | Type | End of Marketing | Last Delivery | End of Service* | Trade in Campaign | Successor Type | Memo |
Magnetic Resonance | NMR | sample changer | SampleMail | all
|
2016 | 2017 | 31.12.2027 | ** | SampleCase™ | |
Magnetic Resonance | NMR | sample changer | SampleRail™ | all
|
2008 | 2005 | 31.12.2020 | ** | Prep2NMR / SampleJet™ | SampleRail |
Magnetic Resonance | NMR | sample changer | BACS | BACS-60 |
2012 | 2014 | 31.12.2016 | ** | SampleXpress™ / SampleCase™ | BACS-60 |
Magnetic Resonance | NMR | sample changer | BACS | BACS-120 | 2012 | 2014 | 31.12.2016 | ** | SampleXpress™ / SampleCase™ | BACS-120 |
Magnetic Resonance | NMR | liquid hander | Bruker LiquidHandler 215 | -- | 2012 | 2015 | 31.01.2020 | ** | SamplePro Tube | LiquidHandler |
Magnetic Resonance |
NMR | sample changer | NMRCase | -- | 2008 | 2008 | 31.12.2018 | ** | SampleCase™ / SampleXpress™ Lite | NMRCase |
Magnetic Resonance | NMR | sample changer | SampleXpress™/ SampleXpress™ Lite | all | 2020 | 2022 | 31.12.2030 | ** | SampleCase Plus |
SampleXpress |
* Further Support possible on a best effort at reasonable endeavor basis
** Please contact your local Bruker representative for further information
⁺ Note: Probes built before the indicated last delivery date may not be repairable anymore, contact Bruker before sending such a probe for repair