Magnet Technology
Helium zero-boil-off and Nitrogen free magnet technology for reduced maintenance costs and longer service intervals
Bore Sizes
A wide range of bore sizes between 11 and 40 cm for investigations on all animals of relevance in preclinical imaging
USR
UltraShield Refrigerated USR magnet technology at field strengths from 4.7 up to 15.2 Tesla for unsurpassed sensitivity in small animal MRI
BioSpec® opens up a whole new world of applications
download now

BioSpec series Bruker offers multi-purpose high field MRI/MRS research systems, designed for the emerging market of preclinical veterinary imaging and molecular MRI

The BioSpec® series is designed for the emerging market of preclinical and molecular MR imaging and MRI research. State-of-the-art MRI CryoProbe™ technology combined with ultra high field USR magnets deliver high spatial resolution in-vivo, thus enabling customers to come closer to the molecular and cellular level research they desire. Thanks to its innovative modular concept, virtually any small animal MR imaging application in life science, biomedical and preclinical research can be conducted. Whatever your application is, the BioSpec series will deliver the optimum solution and equip you perfectly for the most demanding tasks and challenges.   

Features

Features

  • UltraShield Refrigerated USR magnet technology at field strengths from 4.7 up to 15.2 Tesla for unsurpassed sensitivity in small animal MRI
  • A wide range of bore sizes between 11 and 40 cm for investigations on all animals of relevance in preclinical imaging
  • Helium zero-boil-off and Nitrogen free magnet technology for reduced maintenance costs and longer service intervals
  • Scalable AVANCE MRI RF architecture incorporating up to 16 receiver, 4 independent and 8 parallel transmitter channels

Benefits

Benefits

BioSpec benefits from the excellence of Bruker BioSpin, which is the global market and technology leader in analytical magnetic resonance instruments including NMR, preclinical MRI and EPR. The company delivers the world‘s most comprehensive range of magnetic resonance research tools enabling life science, materials science, analytical chemistry, process control and preclinical research. With an install base of over 500 MRI systems worldwide and more than 40 local Bruker offices on all continents, you can rely on our long term expertise as well as on our dedicated aftersales support.

  • Parallel imaging (GRAPPA) for almost all applications including EPI Multiple transmit imaging applications
  • High performance BGA-S gradients with highest amplitudes and slew rates, shim strengths and duty cycles optimized for high field MRI
  • AutoPac: motorized and software controlled animal positioning system for routine handling and increased throughput
  • IntraGate™: self gated, steady-state cardiac imaging (no external sensor hardware and triggering devices required)
  • Phased-array RF coil technology for maximum sensitivity and minimum scan times
  • MRI CryoProbe™ delivering an exceptional increase in sensitivity to in-vivo proven factors of 2.5 to 5.3
  • ParaVision®: intuitive software package, for multi-dimensional MRI/MRS data acquisition, reconstruction, analysis and visualization

Applications

Specifications

General Specifications

  • Actively-shielded superconducting wide-bore magnet
  • Nitrogen free (no cryogenic maintenance by customer)
  • Cryo-refrigerator (Minimal helium consumption, long hold-times, long maintenance intervals)
  • Reduced stray field
  • Screening against external field perturbations
  • Table attached to the magnet front side with integrated rail for animal handling system
  • Passive RT shim system
  • Vibration damping (absorber)
Electronics
  • Bruker Avance digital radio frequency system
  • The digital signal processing system operates at 1H resonance frequency of 500 MHz and utilizes digital filtering, digital quadrature demodulation as well as digital controls for RF amplitude stabilization for superior resolution and image quality
  • Receiver bandwidth: 5 MHz
  • Digital receive channels: up to 16 (optional)
  • 1H RF amplifier: 4000 W pulse power
  • HP workstation
  • High resolution flat screen monito

Webinars

Testimonials

Testimonials

News & Events

More Information

More information

Support

Support

Labscape

Service & Life Cycle Support for Magnetic Resonance and Preclinical Imaging

Bruker’s commitment to provide customers with unparalleled help throughout the buying cycle, from initial inquiry to evaluation, installation, and the lifetime of the instrument is now characterized by the LabScape service concept.

LabScape Maintenance Agreements, On-Site On-Demand and Enhance Your Lab are designed to offer a new approach to maintenance and service for the modern laboratory